Digitizer:Digitizer
Contents
Digitizer is a tool for converting ready (paper) images into digital format.
Digitizer consists of:
- a pad the image is fixed to;
- a pen, or a cursor, used to select a position on the pad.
When moving the cursor across the pad, the digitizer sends the points coordinates to the computer.
You may connect your digitizer to JULIVI system. Using the digitizer, you may add ready pieces to the system database.
It is quite easy to store the pieces in JULIVI system where you can operate different types of pieces and graded nests.
Digitizer Connection
The digitizer is connected to the computer that will be used for entering the pieces into the system.
The digitizer is connected to your computer COM port. For safe operation, install additional PCI controller with COM (RS232) ports into your computer.
Always connect cables from the digitizer to your computer COM port with both the computer and the digitizer disconnected from the power source. Failure to meet this requirement usually results to COM port breakage.
Digitizer Settings
For correct digitizer operation, it shall be adequately set in the system.
A digitizer is usually set after its first connection to the system.
If the digitizer was set before, it is sufficient, in case of a system re-installation, to copy previously saved confarj.ini file where all the digitizer operation settings were saved to C:\Julivi\Constr\ directory.
The setting procedure is as follows:
- Turn on the digitizer power supply.
Pieces Archivingwindow will be displayed.
- In this window, enter material, name group, piece name in the piece parameters and select a size in the sizes scale (you may set any values). Click YES. The workspace window of digitizer program is displayed.
To enter the digitizer settings mode:
- Press simultaneously Ctrl + Alt+F1. Setting Mode red-color message is displayed together with Digitizer Settings window.
Procedure for working in the settings window
1. Select the digitizer type in Type list. The figure above shows one of the options.
2. Select the following parameters in Exchange Parameters block:
Speed of the digitizer data output
Stop Bit – the number of stop bits sent by the digitizer
Data Bit – the number of data bits sent by the digitizer
Control – the parity control used when sending data from the digitizer
These parameters are usually specified in the digitizer documents or are taken from the digitizer settings if there is a setting bar in the digitizer.
The figure above shows one of the options.
3. In ComPort block, select the port the digitizer is physically connected to.
4. Click Ready. Digitizer Settings window will be closed.
5. To read the changed parameters, click Exit in the text panel. The panel may be outside the screen field, but its edge is always seen. To click Exit, point to the lower part of the visible edge of the text panel and left click on it or exit the program using Alt+F4 keys combination from the keyboard.
6. Then, in Error / Clipboard Is Empty warning dialog box, click OK.
7. In Pieces Archiving window again click YES.
8. Re-enter settings mode (Ctrl + Alt+F1).
9. Click Change Matrix Size. Then place the digitizer cursor on the digitizer surface and click any button on the cursor. Four groups of digits will be displayed above Digitizer Settings window.
- Periodically click any cursor button while smoothly moving the cursor to the left boundary of the digitizer table. The value of the first group of digits will decrease. Get to the lowest value (0, if possible).
- Periodically click any cursor button while smoothly moving the cursor to the right boundary of the digitizer table. The value of the second group of digits will increase. Get to the highest value.
- Periodically click any cursor button while smoothly moving the cursor to the bottom boundary of the digitizer table. The value of the third group of digits will decrease. Get to the lowest value (0, if possible).
- Periodically click any cursor button while smoothly moving the cursor to the top boundary of the digitizer table. The value of the fourth group of digits will increase. Get to the highest value.
- Click Finish Measurements and click Yes in Save Matrix Size request dialog box.
10. To read the changed parameters, click Exit. Then, in Error / Clipboard Is Empty warning dialog box, click OK.
11. To calibrate the digitizer, put, using a pencil, four points on the digitizer table distanced 500 mm by length and 500 mm by width. These distances may be more than 500 mm. The more the calibration distance, the more accurate is the digitizer setting. So, for A0 digitizer format, you may mark the points along the whole length at a distance of 900 mm and 700 mm by width. The points shall be put as accurately as possible using accurate measuring devices.
12. Again click YES.
13. Re-enter settings mode (Ctrl + Alt+F1).
14. In Calibration field of Digitizer Settings window, enter the distance between the points marked on the digitizer by length, and in Width line enter the distance between the points marked on the digitizer by width.
15. Click Calibration.
- Left Calibration Point red-color message will be displayed above Digitizer Settings window. Then place the digitizer cursor intersection on point 1 and click any button on the cursor.
- Right Calibration Point red-color message will be displayed above Digitizer Settings window. Then place the digitizer cursor intersection on point 3 and click any button on the cursor.
- Top Calibration Point red-color message will be displayed above Digitizer Settings window. Then place the digitizer cursor intersection on point 2 and click any button on the cursor.
- Bottom Calibration Point red-color message will be displayed above Digitizer Settings window. Then place the digitizer cursor intersection on point 4 and click any button on the cursor.
- Click Ready in Digitizer Settings window and click Yes in Save Calibration Results request dialog box.
16. To read the changed parameters, click Exit. Then, in Error / Clipboard Is Empty warning dialog box, click OK.
17. Again click Archiving.
18. Re-enter settings mode (Ctrl + Alt+F1).
19. Click Set Buttons Codes.
- Grainline and Graded Line Button red-color message will be displayed above Digitizer Settings window. Click a button on the digitizer cursor that will be afterwards used for setting grainline points. For example, 5.
- Intermediate Point Button red-color message will be displayed next above Digitizer Settings window. Click a button on the cursor that will be, afterwards, used for setting intermediate points. For example, 1.
- Final Reference Point Button red-color message will be displayed next above Digitizer Settings window. Click a button on the cursor that will be, afterwards, used for setting final reference points. For example, 2.
- Intermediate Reference Point Button red-color message will be displayed next above Digitizer Settings window. Click a button on the cursor that will be, afterwards, used for setting intermediate reference points. For example, 3.
- Click Ready in Digitizer Settings window and click Yes in Save Button Codes request dialog box.
20. To read the changed parameters, click Exit. Then, in Error / Clipboard Is Empty warning dialog box, click OK.
21. Again click Archiving.
22. Re-enter settings mode (Ctrl + Alt+F1).
23. Click Set Panel Position. Panel Left Top red-color message will be displayed above Digitizer Settings window. Then, place the digitizer cursor intersection on the upper left corner of the text command panel and click any of the set buttons.
24. Panel Right Bottom red-color message will be displayed above Digitizer Settings window. Then, place the digitizer cursor intersection on the right lower corner of the text command panel and click any of the set buttons.
25. Click Ready in Digitizer Settings window.
26. To read the changed parameters, click Exit. Then, in Error / Clipboard Is Empty warning dialog box, click OK.
Digitizer setting is finished.
To check for settings correctness, try to store any of the existing pieces. Then, having saved this piece in Constructor program, measure the distance between the point in the piece by height and width or by diagonals. Compare the measurement results with similar measurements on the existing piece. If the deviation is more than 0.5 mm, repeat calibration procedure.
After correct digitizer setting, it is recommended to save confarj.ini digitizer settings file located in C:\Julivi\Constr\ directory to some other folder for backup files.
Models of Digitizers
There are different models of digitizers. Some of them are listed below.
UVGI -1
To connect this type digitizer, use the following settings:
Type UVGI-16М
Speed –9600
Stop Bit –1
Data Bit – 8
Control – By parity odd
CD9XXX
To connect this type digitizer, use the following settings:
Digitizer type – GTCO-BIN
Speed – 9600
Stop Bit – 1
Data Bit – 8
Control –Without control
The digitizer is set using the built-in control panel.
WARNING! Do not change the internal digitizer settings unless necessary.
Internal Digitizer Setting Diagram
Internal Digitizer Settings Check
- Connect the digitizer to the computer, switch on the power supply. Power button is at the rare panel of the digitizer in the lower left corner. When the power is on, you can hear three short and two long sound signals.
- Place the cursor in the digitizer field. Red indicator is lighted up on the cursor.
This red indicator is lighted up on the cursor in two cases:
1. In the working mode, when the cursor is placed on the working area of the digitizer.
2. In the internal setting mode, when the cursor is placed on
icons and when selecting active lines in the settings panels.
- To check the settings, place the cursor on
icon and press any button. You can hear a short sound signal and the red indicator on the cursor is lighted up.
- Position the cursor on the settings panel lines one by one comparing them with the diagram.
- The red indicator on the cursor is lighted up in the lines that match the lines marked with red circles in the diagram.
- If the settings match, place the cursor on
and click any button. You will hear three short and two long sound signals and the red indicator goes out.
- Start setting the digitizer from Constructor program.
Possible Failures
1. The red indicator is not lighted up when the cursor is placed on the working area of the digitizer.
Restart the system.
- Turn off the digitizer power supply.
- Press and hold the yellow button on the power supply unit at the rare side of the working field and switch on the digitizer.
- Place the cursor on
icon and press any button. You can hear a short sound signal and the red indicator on the cursor is lighted up.
- Place the cursor on the left settings panel and, having selected line 1 in SAVE block, press any button. You can hear three short and two long sound signals and the red indicator goes out.
- Turn off the digitizer.
- Turn on the digitizer. When the power is on, you can hear three short and two long sound signals.
- Place the cursor in the digitizer field. Red indicator is lighted up on the cursor.
- Setting is finished.
2. After the restart, the cursor is inactive when placed in the working field.
Fine-tune the digitizer
- Turn off the digitizer power supply.
- Press and hold the yellow button on the power supply unit at the rare side of the working field and switch on the digitizer.
- Place the cursor on
icon and press any button. You can hear a short sound signal and the red indicator on the cursor is lighted up.
- Position the cursor on the settings panel lines one by one comparing them with the diagram. The red indicator on the cursor is lighted up in the lines that match the lines marked with red circles in the diagram.
- If the settings mismatch, set the digitizer manually.
- Selecting line by line in the panels, press any button to activate the lines that match the diagram and remove the selection of the rest of the lines. . When a line is selected, the red indicator is lighted up on the cursor and you can hear a short sound signal. When deselecting a line, the indicator goes out.
- Place the cursor on the left settings panel and, having selected line 1 in SAVE block, press any button. You can hear three short and two long sound signals and the red indicator goes out.
- To save the settings, place the cursor on
icon and press any button, you can hear three short and two long sound signals.
- Turn off the digitizer.
- Turn on the digitizer. When the power is on, you can hear three short and two long sound signals.
- Place the cursor in the digitizer field. Red indicator is lighted up on the cursor.
- Setting is finished.
E-LINK
To connect this type digitizer, use the following settings:
Digitizer type – E-LINK
Speed exchange– 9600
Stop Bit – 1
Data Bit – 8
Control – Without control
If, before being connected to JULIVI system, the digitizer was operated in the other mode and outputs another protocol, it is necessary to initialize it for correct setting:
1. Enter the digitizer setting program.
2. Turn off the digitizer power supply.
3. Place the cursor in the digitizer field and, holding button 1 pressed, turn on the digitizer power supply. You can hear three short sound signals.
4. Release button 1.
5. Click Initialization in the program. You can hear one sound signal.
6. Click Ready. Digitizer Settings window will be closed.
7. Turn off the digitizer.
After turning off, the digitizer will be configured for operation with JULIVI system.
CALCOMP
Calcomp digitizers of DrawingBoard III -V series usually have GTCO BIN default setting in standard delivery.
The configuration menu on the digitizer corresponds to the table data:
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | |
| A | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||||
| B | 1 | |
1 | 1 | ||||||||||||||
| C | 1 |
1 – Indicator is lighted up when the cursor is placed on the menu button.
With such digitizer setting, you need to specify the following in the program settings:
Digitizer type – GTCO-BIN
Speed – 9600
Stop Bit – 1
Data Bit – 8
Control – By parity odd
Optical Film Digitizer
This digitizer requires less settings if compared with other digitizer types.
Logitech digitizer consists of a transparent film with a number of buttons for the perimeter point parameters, a text panel in the left upper corner, a pen with a reader and a drivers setup disk.
Warning! This type of digitizer does not work with activated antiviral Kaspersky program and with installed Framework 2.
Device Setting
Optical digitizer is set as follows:
1. Connect the digitizer pen reader to the computer via USB.
2. Take off the cap and insert it into the reader.
3. In the tool bar, right click on
and select the following option:
4. Set the parameters as is shown in the figure. Click Apply.
5. Copy the following files from arj folder to c/Julivi/constr4х:
Specific Settings
- Neither calibration, nor adjustment of the digitizer are required. It is fully preset.
Switch off Kaspersky, remove Framework2 and installed dotnetfx.exe
- If the red lamp lights up and the body is vibrating when pressing the pen, change the pen angle without taking it off the film
- Processing – the time between the pen placing on the base and the piece displaying on the screed – is quite long and takes up to 30 sec.
- When archiving, be very careful as a piece is displayed only after placing the pen on the base.