Constructor:Parameters of a point

From Julivi Help
Jump to: navigation, search

Each point has parameters which define its purpose. You can change properties of a point by means of changing its parameters with the help of the functions 105.png in the POINT tab and 106.png the SECTION tab.

The points differ in the system as follows:

  1. by type: end points, intermediate points;
  2. by status of intermediate points: intermediate checkpoints and intermediate points;

for functional points: points dividing a section in ratio and points set at a distance;

3)points with a notch, points without a notch.

Changing type of a point

You can change type of a point from End to Intermediate and vice versa.

To change type of a point:

  • Select the SECTION tab and the button 106.png in this tab. The cursor view is changed to . You can also follow the text menu points "Section/ Divide a section (Join sections)".
  • Specify the point.

When an End point is specified, it is transformed into a Checkpoint, and when an Intermediate point of any status is specified, it is transformed into an End point. So, this function allows to cut and join sections in turn upon repeated clicks in a point.

End points are also called "Cut" points, since they cut a contour into sections.

An opposite task is to join sections. If 2 points are joined, the End point between them becomes of the color of the line and gains status of an Intermediate checkpoint, while the section gets a smooth shape in the break point.

This way, "Cutting" of sections creates a contour break, and "Joining" of sections smoothes out the lines.

For example, if there is no break between the shoulder and the armhole, the shape of the piece will be incorrect. That is why a given point must be set as an End point:

107.png

Changing status of a point

To change status of an intermediate point of any type:

  • Select the SECTION tab and the button 108.png in this tab. The cursor view is changed to 109.png. You can also follow the text menu points "Point/ Change status".
  • Specify the intermediate point. The window for selection of a necessary type of the point is displayed on the screen:
110.png

111.png, 112.png - Checkpoint (and a notch). A point, where an increment can be set.

113.png, 114.png- Intermediate point (and a notch). Does not hold shape of a line when a section is deformed.

115.png, 116.png- Point dividing a section in a ratio (and a notch). Saves a set ratio when length and shape of a section are changed.

117.png, 118.png- Point set at a distance from another point. When the basic point is moved, a point set at a distance will also be moved keeping the distance.

Changing status of a point from Checkpoint to Intermediate can be used when the whole section needs to be deformed upon modification of a curve. For example, when the bottom is widened with its smooth connection to the waistline, the checkpoint on the hip line can be set as intermediate.

Changing status of a point from Intermediate to a Checkpoint is used in an opposite situation, if a part of the section deformed must remain unchanged. To do so, all the section points, which need not to be moved must be set as Checkpoints; for example, when you need to widen a shoulder line in the model, without widening it at the level of the bust.

119.png

FEATURES

  1. If an end point is specified, only the first type of points will be activated (Checkpoints) to change type of point with a notch and vice versa, because this window is meant to change status of intermediate points.
  2. If you change status of any intermediate point to a functional point "Set at a distance" - it will be "tied" to the beginning point of a given section.

Parameters of a point, dividing a section in ratio

To change parameters of a Functional point "Dividing a section in ratio":

  • Select the POINT tab and the button 120.png in the tab. The cursor view is changed to 121.png. You can also follow the text menu points "Point/ Parameters of the point dividing a section in ratio".
  • Specify the point of the type "Dividing a section in ratio". The window for input of data is displayed on the screen:
13.png
  • Input a new ratio in the line for input of data. To view an actual ratio, press the button Embim1459.png. The following window will be maximized:
123.png

You can input values different in size manually or from the saved buffer with pressing the button Embim1484.png. You can restore the initially set value with pressing the button 50.png .

If you don't need to input different values by sizes, the input window can be minimized with pressing the button Embim1622.png after viewing the actual ratio.


  • Press the YES button to change parameters, press CANCEL to cancel an action.

FEATURES A maximized window for input of data (the button Embim1459.png) for this function is displayed on a yellow background, because the table contains nonlinear values - coefficients.


When creating a "Seam algebra" buffer for a given function, you should consider the type of tab. To change the tab type from "Linear value" (i.e. length) to "Coefficient", click the right mouse button in any place of the values table. An additional menu is displayed on the screen, where you can change the tab type with clicking a necessary line:

126.png

Parameters of a point, set at distance

To change parameters of a functional point "Set at distance":

  • Select the POINT tab and the button 127.png in the tab. The cursor view is changed to 129.png

You can also follow the text menu points "Point /Parameters of a point set at distance".


  • Specify the basic point (reference anchor point, from which the distance is set)
  • Specify the point of the type "Set at distance". The window for input of data is displayed on the screen:
128.png
  • Set the distance between the functional point and the reference point (of any type) in the input line

The sign for performance of the command is defined as follows:

If the basic point is an Intermediate point, the indention values are accepted with any sign. The Functional point will be moved clockwise (with "+") and counter-clockwise (with "-") from the basic point along the contour.

130.png

If the basic point is an End point, only previous initial direction of the indention is applicable.

  • To preview the actual indention press the button Embim1459.png.

A maximized window is displayed on the screen, where you can input values by sizes manually or from the buffer with pressing the button Embim1484.png. You can restore the initially set value with pressing the button 50.png.

  • Press the YES button to confirm input of data, press CANCEL to cancel the action.

FEATURES You cannot only change the distance from the reference point, but to anchor the point to a different point of the given section (by specifying it as an initial one).

Make (remove) a notch

To make or remove a notch:

  • Select the POINT tab and the button 131.png in it. The cursor view is changed to 132.png. You can also follow the text menu points "Point/ Make (remove) a notch".
  • Specify the point. The point is transformed into a notch. If a point with a notch is specified, the notch will be removed.