Difference between revisions of "Design:General description of program operations"

From Julivi Help
Jump to: navigation, search
(→‎The “Initial Data” Table for the Construction)
(→‎Inputting data from Size database)
Line 104: Line 104:
  
 
 
 
 
−
=== Inputting data from Size database ===  
+
=== Data entry from the Sizes Database ===
 +
 
 +
     When the [[Image:design116.png|design116.png]] command is chosen, the screen will display the window of measures for this sizes database and their values for the chosen size, height and fullness.
 +
 
 +
     Double-click on the appropriate line to choose the measurement data, which will be used in the construction. The lines containing the chosen measurement data are highlighted in color. Double-click on the selected line again to deselect it.
 +
 
 +
 
 +
<center>&nbsp;[[Image:design117.png|design117.png]]</center>
 +
 
 +
&nbsp;In the lower left corner of the window the following buttons are located:
 +
 
 +
&nbsp;[[Image:design118.png|design118.png]]&nbsp;- Select all the data in the table&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; [[Image:design119.png|design119.png]]&nbsp;- Deselect the selected data completely
 +
 
 +
&nbsp;[[Image:design120.png|design120.png]]&nbsp;- Change of the line size when working with long names. For this purpose you have to move the cursor in the table head, having indicated the window boundary line and extending it, and holding down the left mouse button. After the desired window size is set, release the button.
 +
 
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; When you press the '''Yes''' button''', '''the chosen values will be entered into the initial data of the project.
 +
 
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; If the '''Sizes Database '''was used to choose the initial data of the project, then you can enter the relevant values from the sizes database into the initial data with the help of the [[Image:design121.png|design121.png]]&nbsp;selection fields. A size/height/fullness value will be called up:
 +
<center> [[Image:design122.png|design122.png]]</center>
 +
 
 +
To confirm the choice, press the [[Image:design123.png|design123.png]]&nbsp;button.
 +
 
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; After filling in the table or making any changes or additions to it, press the '''Yes '''button to confirm your action, or press the '''Cancel '''button to cancel your action.
 +
 
 +
&nbsp;
 +
 
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; When the table is being filled in, the program controls repetition of symbols in the '''Measurement Data''', '''Increments''' '''and Constants''', and '''Variables''' tabs. If a parameter is assigned a symbol that has already been used above, the following message will be displayed:
 +
 
 +
 
 +
&nbsp;<center> [[Image:design124.png|design124.png]] </center>
 +
 
 +
If it is necessary to work with identical symbols, press the '''Yes '''button. In such a case you have to remember that a certain sequence of reading data is set in the program: first the '''Measurement Data''', then the '''Increments''', and then the '''Variables'''.
 +
 
 +
Example: If you enter the waist circumference (Wc) in the '''Measurement Data''' and then enter the (Wc + 3) expression under the same name of Wc in the '''Variables''' section, then as the result of that we’ll see only the last configuration: (Wc + 3) when commands are performed in the project and when we access the Wc symbol in <u>any</u> initial data, either in the measurement data or in the variables.
 +
 
 +
 
 +
{| style="border-spacing:0;"
 +
| style="background-color:#ffffff;"|
 +
{| style="border-spacing:0;"
 +
|| ===== ATTENTION =====
 +
 
 +
 
 +
|}
 +
&nbsp;
 +
 
 +
|}
 +
&nbsp;
 +
 
 +
 
 +
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; '''When working with the “Initial Data” table in a project containing a Sizes Database (where there is a list of symbols), you have to make sure that the symbols added manually and chosen from the Sizes Database (<u>and even those which have not been chosen</u>) do not duplicate!!! '''
 +
 
 +
&nbsp;
 +
 
 +
Example: In the Sizes Database chosen for the project there is a symbol in the “'''Measurement Data'''” tab: “Vst” for “Nipple point height”. But this value is not relevant for this project, and it <u>was not chosen in the work list</u>. If you add a value manually in the “ '''Increments''' '''and Constants''' ” tab, e.g. “Collar stand height”, and introduce the same “Vst” symbol for it, the following will happen: During work with this project the information will be read from the chosen Sizes Database, which means that when the collar is drafted, the “Nipple point height” value will be read instead of the “Collar stand height” data!!!
 +
 
 +
&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;The [[Image:design125.png|design125.png]]&nbsp;button allows you to save data from the table in electronic format (Measurement data, increments, variables, identifiers) with the possibility of printing the data out.
 +
 
 
=== Changing reference data ===
 
=== Changing reference data ===
  

Revision as of 17:43, 15 April 2015

The constructor works with a project in the "Design" program. The project is essentially a certain algorithm of constructing the base framework and a table of the initial data used for its construction. The data table is pre-filled in by the constructor. You can enter individual data inside the project or call them up from the previously created databases of measures. The construction algorithm is formed by the program of the actions that the constructor performs on the screen.

Creating a New Project

      Work in the program begins with creating a new project. To create a new project you have to:

§  Choose the Project / New menu item. A window for entering the project parameters will be displayed on the screen:

 


 design87.png

          1) In the Construction Type field, choose the “Base Construction” type (it is chosen by default), which relates directly to construction of base frameworks. The “Piece”, “Contour Plotting” and “Contour Modification” modes are meant for creating macrocommands in the “Constructor” program.

          2) In the Name field, enter the name of the project. It may be any kind of name, but you can’t use quotation marks in it.

          3) In the Group field, enter a name that combines several projects into one group on some basis. For example, in the TSNIISHP group all the projects can be combined, which are constructed according to this procedure of constructing. You can enter up to 30 symbols into this field.

         Even if the projects are in different groups, their names must not duplicate. A message will be displayed on the screen. Enter a new name for the group project after pressing the ОК button.


    
design88.png

         4) The Sizes Database switch allows using the previously entered measures database as initial data for the project. For example, the measures database filled in according to the data of OST 17-326-81: “Typical Figures of Women”.

design89.png

If individual measures are used while creating the project, the switch is not activated, and the initial data are entered inside the project.

5) In case if some part of a previously created project, or the entire project, has to be copied while creating the project, activate the “Copy data from:” option.

There is a possibility to choose one of the previously created projects as a prototype.

design90.pngdesign91.png 

During copying of the project the switches become active that determine which part of the project has to be copied. If some element is not required, the relevant item is deselected:

design92.png

      6) For entering the sketches of outer appearance the right part of the window is used.

design93.png

Here sketches of any format (ВМР, JPG, GIF…) can be used, acquired in any way: from a scanner or from a digital camera, and saved in a file.

                                         Buttons for working with the Outer Appearance window:

design94.png - Scan the image                                      design95.png - Scanner settings.

design96.png - Read the sketch from the file                 design97.png - Read the sketch from the buffer 

design98.png - Save the image in a file                          design99.png  - Record the image in the buffer

design100.png] - Zoom in                                                  design101.png  - Zoom out 

design102.png  - Show the general view of the sketch      design103.png  - Print the sketch out

 

§  When the project parameters have been filled in, press the Yes button. The created project will be displayed in the work window of the program immediately, and its name will be written on the upper bar of the window.

The “Initial Data” Table for the Construction

Before starting work you have to fill in the table of data that will be used in the construction (or check them if the data were copied). For this purpose you have to fulfill the “Project / Initial Data” menu item or choose the design104.png command in the button menu on the left. A data entry table consisting of four tabs will be displayed on the screen:

 design105.png

1.      Measurement Data – for entering the values of measurement data used in the construction;

2.      Increments and Constants – for entering the increments and constant values for the project;

3.      Variables – for entering the values obtained by calculation method (formulas);

4.      Identifiers – no values are entered in this tab. It allows to view and use the data of the measurements performed in the process of constructing the framework and recorded as variable values.

 

To go to a certain tab, press the field with its name.

The table is filled in the following way: enter a symbol for the value into the Symbol field, a numerical value or a calculation formula into the Value field, and a definition of the value or a comment into the Name field. To move through the data table, and also to edit the table, you can use these buttons:   

                                               design106.png

design107.png - move to top of list;                                                  design108.png - move one line up;

design109.png - move one line down;                                              design110.png - move to end of list;

design111.png - add a new value;                                                      design112.png - delete a value;

design113.png - transfer a value one line up;                                    design114.png - transfer a value one line down;  

 

For complete view of long text in a line the table cells can be widened by holding the cursor on the cell boundary and shifting it for the desired width.


 
design114_1.png

      You can change the initial data of the project, and obtain construction of framework for a different size.

      You can fill in the table either “manually”, or using the measures databases from the “Sizes Databases” program (e.g., the database of OST 17-326-81– “Typical Figures of Women”).

      To change the measures database of the project, press the design115.png button and choose the relevant database in the list.

 

ATTENTION: data of another chosen measures database will be read correctly in this project only in case of exact match of all the names of measures in the Sizes Database and the “Initial Data” table of the project.

 

Data entry from the Sizes Database

     When the design116.png command is chosen, the screen will display the window of measures for this sizes database and their values for the chosen size, height and fullness.

     Double-click on the appropriate line to choose the measurement data, which will be used in the construction. The lines containing the chosen measurement data are highlighted in color. Double-click on the selected line again to deselect it.


 design117.png

 In the lower left corner of the window the following buttons are located:

 design118.png - Select all the data in the table                   design119.png - Deselect the selected data completely

 design120.png - Change of the line size when working with long names. For this purpose you have to move the cursor in the table head, having indicated the window boundary line and extending it, and holding down the left mouse button. After the desired window size is set, release the button.

      When you press the Yes button, the chosen values will be entered into the initial data of the project.

      If the Sizes Database was used to choose the initial data of the project, then you can enter the relevant values from the sizes database into the initial data with the help of the design121.png selection fields. A size/height/fullness value will be called up:

design122.png

To confirm the choice, press the design123.png button.

      After filling in the table or making any changes or additions to it, press the Yes button to confirm your action, or press the Cancel button to cancel your action.

 

       When the table is being filled in, the program controls repetition of symbols in the Measurement Data, Increments and Constants, and Variables tabs. If a parameter is assigned a symbol that has already been used above, the following message will be displayed:


 
design124.png

If it is necessary to work with identical symbols, press the Yes button. In such a case you have to remember that a certain sequence of reading data is set in the program: first the Measurement Data, then the Increments, and then the Variables.

Example: If you enter the waist circumference (Wc) in the Measurement Data and then enter the (Wc + 3) expression under the same name of Wc in the Variables section, then as the result of that we’ll see only the last configuration: (Wc + 3) when commands are performed in the project and when we access the Wc symbol in any initial data, either in the measurement data or in the variables.


===== ATTENTION =====


 

 


                               When working with the “Initial Data” table in a project containing a Sizes Database (where there is a list of symbols), you have to make sure that the symbols added manually and chosen from the Sizes Database (and even those which have not been chosen) do not duplicate!!!

 

Example: In the Sizes Database chosen for the project there is a symbol in the “Measurement Data” tab: “Vst” for “Nipple point height”. But this value is not relevant for this project, and it was not chosen in the work list. If you add a value manually in the “ Increments and Constants ” tab, e.g. “Collar stand height”, and introduce the same “Vst” symbol for it, the following will happen: During work with this project the information will be read from the chosen Sizes Database, which means that when the collar is drafted, the “Nipple point height” value will be read instead of the “Collar stand height” data!!!

      The design125.png button allows you to save data from the table in electronic format (Measurement data, increments, variables, identifiers) with the possibility of printing the data out.

Changing reference data

Performing operations with a project

Opening a project

Copying a project

Changing project parameters

Deleting a project

Saving a project